| Item | Technical Data |
|---|---|
| Working Principle | Heat Pump |
| Water Evaporation Rate | 6.25 L/hour |
| Water Evaporation Capacity (24 hours) | 150 Litres |
| Heat Exchanger Type | By Immersion |
| Approximate Dimensions (L × W × H) | 1200 × 900 × 1800 mm |
| Energy Consumption | 160–190 W per litre evaporated |
| Installed Power | 6 kW |
| Maximum Ambient Temperature | 40°C |
| Step | Description |
|---|---|
| 1️⃣. Submit Wastewater Information | The client fills out a form and describes the type of wastewater to be tested. |
| 2️⃣. Sample Collection | TVTS collects samples at the factory or the client sends them to the TVTS pilot facility. |
| 3️⃣. Pilot Test Operation (HPVE System) | TVTS engineers operate the pilot unit and record COD, TDS, and energy consumption data. |
| 4️⃣. Technical Report & Investment Consultation | TVTS provides a detailed technical report along with an optimized system proposal (CAPEX – OPEX – ROI). |
💡Assignment: The requirement is to treat an acidic wastewater stream. To achieve efficiency in treating acidic wastewater streams, evaporation at very low temperatures is necessary. The proposed solution is to use a vacuum heat pump evaporator (HPVE).
💧 Wastewater samples tested: high COD levels (COD > 20,000 mg/L, TDS > 10,000 mg/L).
| Parameter | Inlet | Pre-Treatment | Degassing | Evaporation | RO Stage 1 | RO Stage 2 |
|---|---|---|---|---|---|---|
| pH | 6.0 | 9.27 | 9.5 | 6.3 | 6.9 | 7.05 |
| EC (µS/cm) | 7,820 | 17,400 | 18,200 | 682 | 125 | 33.9 |
| Ca²⁺ (mg/L) | 2,940 | 0 | – | – | – | – |
| NH₃ (mg/L) | 780 | 590 | 550 | 84 | 13.7 | 7.4 |
Water recovery efficiency after evaporation: ≈ 80%
Note:
All wastewater samples must be prepared in a minimum volume of 1,000 liters to ensure a stable and continuous pilot testing process.
The data obtained are used directly for system design, ROI calculation, and optimization of full-scale industrial capacity.
✅ Pilot system designed and manufactured by TVTS, simulating real industrial systems.
✅ Direct operation and data analysis by expert engineers.
✅ Testing can be conducted at the TVTS factory or at the customer’s plant.
✅ Provides real-time COD, TDS, energy, and OPEX reports.
✅ Free system configuration consultation and post-pilot quotation.
REGISTER FOR A PILOT TEST RUN